| 在线有毒气体监测仪 型号:M264307 | | Protecting peopleassets from hydrocarbons
The infrared absorption method of detection is ideal for the detection of larger hydrocarbon molecules such as fuels. It features enough sensitivity to expand the range of application into the ppm range. For instance fuels such as gasoline, diesel or kerosene are mixtures of hydrocarbons.
Infrared gas detection theory of operation
Some gases absorb light at a certain wavelength colour. This absorption band is specific to the gas. The rate of the absorption depends not only on the substance to be detected but also on the number of gas molecules i.e. the concentration of the gas. This premise is used to detect gases. For example, the C - H bond in hydrocarbon molecules will oscillateabsorb light at 3, 4 mm. This fact makes it so easy to detect fuels. Hexane, for instance has 14 C - H bonds compared to Methane that has only 4!
A light beam is directed through a cuvette filled with the gas to be detected. The more hydrocarbons present, the more light will be absorbed. A photo detector at the other end of the cuvette measures the remaining light intensity. The difference between the originalremaining light intensity corresponds to the gas concentration.
A reference beam with a different wavelength compensates for potential interferences of dust, humidity or variations of intensity from the light source.
Fail-safe technology
Failure of important components such as the light source or photo detector will trigger a "system fail" alarm. Most local authorities will accept this as a self-diagnostic feature. Systems including a self-check require less maintenancecalibration, saving timemoney.
Simple maintenance: Easy to read displaynon-Vintrusive calibration
The bright LED display of the Statox 501 IR shows the gas concentration in percent L.E.L. Lower Explosion Limit. An important accessory is the calibration adapter, featuring control buttons operating Hall-sensors inside the Ex d housing. The service menu is password protected preventing unauthorised access. All parameters can be checkedchanged, or a calibration can be done all without opening the transmitter. The adapter is also equipped with a gas outlet so that it can be used for flow-through applications.
Impervious compact design
The dimensions of the Statox 501 IR are smallcompact. The sensor compartment is completely sealed, not allowing dust or insects to enter. It is located in the center of the sensor head. This allows heat radiation from the electronicsthe infrared lamp to keep the unit a few degrees above the ambient temperature thus avoiding condensation. This innovative design makes any additional heating unnecessary, allowing the sensor head to be very energy efficient. This saves additional money by eliminating more expensive wiringa bigger power supply that would otherwise be necessary.
The sensor head is rated protection class IP 67 6 = protection even against fine dust, 7 = submerged 1 m deep in water for 30 minutes. You can have confidence that this system will safely operate even in the harshest environment.
|
|
 |